Known Issues ------------ - The first few bytes of a message are lost coming out of sleep. See "Sleep Mode" in the Modbus Overview section of the Modbus Probe Interface Manual Note an alternative workaround to this problem instead of retransmissions is to transmit some data prior to sending the message. Suggestion is to transmit a single 0xFF byte as the wakeup character and then wait the minimum 3.5 character periods. ------------------------------ Release Notes for Modbus 2.0.3 ------------------------------ FEATURES: - none ENHANCEMENTS: - none FIXES: - Changes for compatibility with latest production boards (DND-47, DND-48, DND-49) ------------------------------ Release Notes for Modbus 2.0.2 ------------------------------ FEATURES: - none ENHANCEMENTS: - none FIXES: - Fix RS232 driver not disabled on wake for RS485 mode (DND-6) - Some probes may have temperature sensors with readings outside the accuracy specification (DND-24) ------------------------------ Release Notes for Modbus 2.0.1 ------------------------------ First Release.